The Zürich experience: one decade of three-dimensional high-resolution computed tomography
Top Magn Reson Imaging
. 2002;13(5):307-322
Abstract
No abstract.
Links
PubMed:
12464744
Cited Works (58)
Year
Entry
1990
Goldstein SA, Hollister SJ, Kuhn JL, Kikuchi N. The mechanical and remodeling properties of trabecular bone. In: Mow VC, Ratcliffe A, Woo SL-Y, eds.
Biomechanics of Diarthrodial Joints
. Vol 2. New York, NY: Springer-Verlag; 1990:61-81.
1985
Gibson LJ. The mechanical behaviour of cancellous bone.
J Biomech
. 1985;18(5):317-328.
1993
Engelke K, Graeff W, Meiss L, Hahn M, Delling G. High spatial resolution imaging of bone mineral using computed microtomography: comparison with microradiography and undecalcified histologic sections.
Invest Radiol
. April 1993;28(4):341-349.
1996
Müller R, Hildebrand T, Häuselmann HJ, Rüegsegger P. In vivo reproducibility of three‐dimensional structural properties of noninvasive bone biopsies using 3D‐pQCT.
J Bone Miner Res
. November 1996;11(11):1745-1750.
1996
Rüegsegger P, Koller B, Müller R. A microtomographic system for the nondestructive evaluation of bone architecture.
Calcif Tiss Int
. 1996;58(1):24-29.
2002
Pistoia W, van Rietbergen B, Lochmüller E-M, Lill CA, Eckstein F, Rüegsegger P. Estimation of distal radius failure load with micro-finite element analysis models based on three-dimensional peripheral quantitative computed tomography images.
Bone
. June 2002;30(6):842-848.
1990
Odgaard A, Andersen K, Melsen F, Gundersen HJG. A direct method for fast three-dimensional serial reconstruction.
J Microsc
(Oxford). September 1990;159(pt 3):335-342.
1993
Dalstra M, Huiskes R, Odgaard A, van Erning L. Mechanical and textural properties of pelvic trabecular bone.
J Biomech
. April–May 1993;26(4-5):523-535.
1987
Lorensen WE, Cline HE. Marching cubes: a high resolution 3D surface construction algorithm.
Comput Graph
. 1987;21(4):163-169.
1999
Laib A, Rüegsegger P. Calibration of trabecular bone structure measurements of in vivo three-dimensional peripheral quantitative computed tomography with 28-μm-resolution microcomputed tomography.
Bone
. January 1999;24(1):35-39.
1990
Keyak JH, Meagher JM, Skinner HB, Mote CD Jr. Automated three-dimensional finite element modelling of bone: a new method.
J Biomed Eng
. 1990;12(5):389-397.
1996
Müller R, Hahn M, Vogel M, Delling G, Rüegsegger P. Morphometric analysis of noninvasively assessed bone biopsies: comparison of high-resolution computed tomography and histologic sections.
Bone
. March 1996;18(3):215-220.
1994
Goulet RW, Goldstein SA, Ciarelli MJ, Kuhn JL, Brown MB, Feldkamp LA. The relationship between the structural and orthogonal compressive properties of trabecular bone.
J Biomech
. April 1994;27(4):375-389.
1997
Laib A, Hildebrand T, Häuselmann HJ, Rüegsegger P. Ridge number density: a new parameter for in vivo bone structure analysis.
Bone
. December 1997;21(6):541-546.
1994
Guilak F. Volume and surface area measurement of viable chondrocytes in situ using geometric modelling of serial confocal sections.
J Microsc
(Oxford). March 1994;173(3):245-256.
1994
Mullender MG, Huiskes R, Weinans H. A physiological approach to the simulation of bone remodeling as a self-organizational control process.
J Biomech
. November 1994;27(11):1389-1394.
1995
Kinney JH, Lane NE, Haupt DL. In vivo, three‐dimensional microscopy of trabecular bone.
J Bone Miner Res
. February 1995;10(2):264-270.
1994
Müller R, Hildebrand T, Rüegsegger P. Non-invasive bone biopsy: a new method to analyse and display the three-dimensional structure of trabecular bone.
Phys Med Biol
. January 1994;39(1):145-164.
1997
Ulrich D, Hildebrand T, Van Rietbergen B, Müller R, Rüegsegger P. The quality of trabecular bone evaluated with micro-computed tomography, FEA and mechanical testing.
Stud Health Technol Inform
. 1997;40:97-112.
1997
Camacho DLA, Hopper RH, Lin GM, Myers BS. An improved method for finite element mesh generation of geometrically complex structures with application to the skullbase.
J Biomech
. 1997;30(10):1067-1070.
1991
Ciarelli MJ, Goldstein SA, Kuhn JL, Cody DD, Brown MB. Evaluation of orthogonal mechanical properties and density of human trabecular bone from the major metaphyseal regions with materials testing and computed tomography.
J Orthop Res
. May 1991;9(5):674-682.
1985
Beaupre GS, Hayes WC. Finite element analysis of a three-dimensional open-celled model for trabecular bone.
J Biomech Eng
. August 1985;107(3):249-256.
1993
Marks LW, Gardner TN. The use of strain energy as a convergence criterion in the finite element modelling of bone and the effect of model geometry on stress convergence.
J Biomed Eng
. November 1993;15(6):474-476.
1999
Ulrich D, van Rietbergen B, Laib A, Rüegsegger P. Load transfer analysis of the distal radius from in-vivo high-resolution CT-imaging.
J Biomech
. August 1999;32(8):821-828.
1997
Hildebrand T, Rüegsegger P. Quantification of bone microarchitecture with the structure model index.
Comput Methods Prog Biomed
. 1997;1(1):15-23.
1991
Durand EP, Rüegsegger P. Cancellous bone structure: analysis of high-resolution ct images with the run-length method.
J Comput Assist Tomogr
. January–February 1991;15(1):133-139.
1976
Dalén N, Hellström L-G, Jacobson B. Bone mineral content and mechanical strength of the femoral neck.
Acta Orthop Scand
. 1976;47(5):503-508.
1991
Hayes WC, Piazza SJ, Zysset PK. Biomechanics of fracture risk prediction of the hip and spine by quantitative computed tomography.
Radiol Clin North Am
. 1991;29(1):1-18.
1983
Parfitt AM, Mathews CH, Villanueva AR, Kleerekoper M, Frame B, Rao DS. Relationships between surface, volume, and thickness of iliac trabecular bone in aging and in osteoporosis: implications for the microanatomic and cellular mechanisms of bone loss.
J Clin Invest
. October 1983;72(4):1396-1409.
1994
Bonse U, Busch F, Günnewig O, Beckmann F, Pahl R, Delling G, Hahn M, Graeff W. 3D computed X-ray tomography of human cancellous bone at 8 μm spatial and 10
−4
energy resolution.
Bone Miner
. April 1994;25(1):25-38.
1984
Harrigan TP, Mann RW. Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor.
J Mater Sci
. March 1984;19(3):761-767.
1892
Wolff J. Das Gesetz der Transformation der Knochen. Berlin: Hirschwald; 1892.
1992
Turner CH. On Wolff's law of trabecular architecture.
J Biomech
. January 1992;25(1):1-9.
1990
Turner CH, Cowin SC, Rho JY, Ashman RB, Rice JC. The fabric dependence of the orthotropic elastic constants of cancellous bone.
J Biomech
. 1990;23(6):549-561.
1992
Chevalier F, Laval-Jeantet AM, Laval-Jeantet M, Bergot C. CT image analysis of the vertebral trabecular network in vivo.
Calcif Tiss Int
. July 1992;51(1):8-13.
1997
Hildebrand T, Rüegsegger P. A new method for the model-independent assessment of thickness in three-dimensional images.
J Microsc
(Oxford). 1997;185(1):67-75.
1984
Hart RT, Davy DT, Heiple KG. Mathematical modeling and numerical solutions for functionally dependent bone remodeling.
Calcif Tiss Int
. March 1984;36(suppl 1):S104-S109.
1997
Simmons CA, Hipp JA. Method-based differences in the automated analysis of the three-dimensional morphology of trabecular bone.
J Bone Miner Res
. June 1997;12(6):942-947.
1982
Williams JL, Lewis JL. Properties and an anisotropic model of cancellous bone from the proximal tibial epiphysis.
J Biomech Eng
. February 1982;104(1):50-56.
1992
Weinans H, Huiskes R, Grootenboer HJ. The behavior of adaptive bone-remodeling simulation models.
J Biomech
. December 1992;25(12):1425-1441.
1989
Feldkamp LA, Goldstein SA, Parfitt MA, Jesion G, Kleerekoper M. The direct examination of three‐dimensional bone architecture in vitro by computed tomography.
J Bone Miner Res
. 1989;4(1):3-11.
1994
Hollister SJ, Brennan JM, Kikuchi N. A homogenization sampling procedure for calculating trabecular bone effective stiffness and tissue level stres.
J Biomech
. 1994;27(4):433-444.
1999
Hildebrand T, Laib A, Müller R, Dequeker J, Rüegsegger P. Direct three-dimensional morphometric analysis of human cancellous bone: microstructural data from spine, femur, iliac crest, and calcaneus.
J Bone Miner Res
. July 1999;14(7):1167-1174.
1990
Mosekilde L. Consequences of the remodelling process for vertebral trabecular bone structure: a scanning electron microscopy study (uncoupling of unloaded structures).
Bone Miner
. July 1990;10(1):13-35.
1998
Müller R, Gerber SC, Hayes WC. Micro-compression: a novel technique for the nondestructive assessment of local bone failure.
Technol Health Care
. December 1998;6(5-6):433-444.
1990
Jensen KS, Mosekilde L, Mosekilde L. A model of vertebral trabecular bone architecture and its mechanical properties.
Bone
. 1990;11(6):417-423.
1995
van Rietbergen B, Weinans H, Huiskes R, Odgaard A. A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models.
J Biomech
. January 1995;28(1):69-81.
1993
Odgaard A, Gundersen HJG. Quantification of connectivity in cancellous bone, with special emphasis on 3-D reconstructions.
Bone
. March–April 1993;14(2):173-182.
1996
Müller R, Koller B, Hildebrand T, Laib A, Gianolini S, Rüegsegger P. Resolution dependency of microstructural properties of cancellous bone based on three-dimensional μ-tomography.
Technol Health Care
. April 1996;4(1):113-119.
1999
Van Rietbergen B, Müller R, Ulrich D, Rüegsegger P, Huiskes R. Tissue stresses and strain in trabeculae of a canine proximal femur can be quantified from computer reconstructions.
J Biomech
. February 1999;32(2):165-173.
1987
Huiskes R, Weinans H, Grootenboer HJ, Dalstra M, Fudala B, Slooff TJ. Adaptive bone-remodeling theory applied to prosthetic-design analysis.
J Biomech
. 1987;20(11-12):1135-1150.
2001
Pistoia W, van Rietbergen B, Laib A, Rüegsegger P. High-resolution three-dimensional-pqct images can be an adequate basis for in-vivo μfe analysis of bone.
J Biomech Eng
. October 2001;123(2):176-183.
1986
Fyhrie DP, Carter DR. A unifying principle relating stress to trabecular bone morphology.
J Orthop Res
. 1986;4(3):304-317.
1995
Müller R, Rüegsegger P. Three-dimensional finite element modelling of non-invasively assessed trabecular bone structures.
Med Eng Phys
. March 1995;17(2):126-133.
2000
Huiskes R, Ruimerman R, van Lenthe GH, Janssen JD. Effects of mechanical forces on maintenance and adaptation of form in trabecular bone.
Nature
. June 8, 2000;405(6787):704-706.
1970
McElhaney JH, Fogle JL, Melvin JW, Haynes RR, Roberts VL, Alem NM. Mechanical properties of cranial bone.
J Biomech
. 1970;3(5):495-511.
1987
Cheal EJ, Snyder BD, Nunamaker DM, Hayes WC. Trabecular bone remodeling around smooth and porous implants in an equine patellar model.
J Biomech
. 1987;20(11-12):1121-1134.
1998
Laib A, Häuselmann HJ, Rüegsegger P. In vivo high resolution 3D-QCT of the human forearm.
Technol Health Care
. 1998;6(5-6):329-337.
Cited By (9)
Year
Entry
2006
Stauber M, Müller R. Volumetric spatial decomposition of trabecular bone into rods and plates: a new method for local bone morphometry.
Bone
. 2006;38(4):475-484.
2007
Buie HR, Campbell GM, Klinck RJ, MacNeil JA, Boyd SK. Automatic segmentation of cortical and trabecular compartments based on a dual threshold technique for in vivo micro-CT bone analysis.
Bone
. October 2007;41(4):505-515.
2010
Nishiyama KK, Macdonald HM, Buie HR, Hanley DA, Boyd SK. Postmenopausal women with osteopenia have higher cortical porosity and thinner cortices at the distal radius and tibia than women with normal aBMD: an in vivo HR-pQCT study.
J Bone Miner Res
. April 2010;25(4):882-890.
2006
Stauber M, Müller R. Age-related changes in trabecular bone microstructures: global and local morphometry.
Osteoporos Int
. April 2006;17(4):616-626.
2010
Laffosse J-M, Kinkpe C, Gomez-Brouchet A, Accadbled F, Viguier E, Sales de Gauzy J, Swider P. Micro-computed tomography study of the subchondral bone of the vertebral endplates in a porcine model: correlations with histomorphometric parameters.
Surg Radiol Anat
. 2010;32(4):335-341.
2005
Stauber M.
Volumetric Spatial Decomposition of Porous Microstructures: A Framework for Element Based Analysis of Trabecular Bone
[PhD thesis]. Swiss Federal Institute of Technology Zürich; 2005.
2013
Toal VR.
The Mechanics of Microdamage and Microfracture in Trabecular Bone
[PhD thesis]. Brisbane, Australia: Queensland University of Technology; September 2013.
2007
MacNeil JAM.
Clinical Assessment of Bone Quality
[PhD thesis]. Calgary, AB: University of Calgary; June 2007.
2012
Nishiyama KKS.
In Vivo Assessment of Bone Microarchitecture and Estimated Bone Strength
[PhD thesis]. Calgary, AB: University of Calgary; October 2012.