wbldb
home
|
authors
|
theses
Birnbaum, K.; Sindelar, R.; Gärtner, J. R.; Wirtz, D. C.
Material properties of trabecular bone structures
Surg Radiol Anat
. 2001;23(6):399-407
Keywords
Keywords:
Bone; Compressive strength; Hip joint replacement; Material anisotropy; Trabecular structure
Links
DOI:
10.1007/s00276-001-0399-x
PubMed:
11963622
WoS:
000174472600006
Cited Works (21)
Year
Entry
1990
Choi K, Kuhn JL, Ciarelli MJ, Goldstein SA. The elastic moduli of human subchondral, trabecular, and cortical bone tissue and the size-dependency of cortical bone modulus.
J Biomech
. 1990;23(11):1103-1113.
1998
Zysset PK, Guo XE, Hoffler CE, Moore KE, Goldstein SA. Mechanical properties of human trabecular bone lamellae quantified by nanoindentation.
Technol Health Care
. December 1998;6(5-6):429-432.
1974
Schoenfeld CM, Lautenschlager EP, Meyer PR. Mechanical properties of human cancellous bone in the femoral head.
Med Biol Eng
. 1974;12(3):313-317.
1973
Pugh JW, Rose RM, Radin EL. Elastic and viscoelastic properties of trabecular bone: dependence on structure.
J Biomech
. 1973;6(5):475-485.
1987
Goldstein SA. The mechanical properties of trabecular bone: dependence on anatomic location and function.
J Biomech
. 1987;20(11-12):1055-1061.
1999
Sugita H, Oka M, Toguchida J, Nakamura T, Ueo T, Hayami T. Anisotropy of osteoporotic cancellous bone.
Bone
. May 1999;24(5):513-516.
1957
Evans FG, Lebow M. Strength of human compact bone under repetitive loading.
J Appl Physiol
. January 1957;10(1):127-130.
1991
Lotz JC, Gerhart TN, Hayes WC. Mechanical properties of metaphyseal bone in the proximal femur.
J Biomech
. 1991;24(5):317-329.
1995
Lotz JC, Cheal EJ, Hayes WC. Stress distributions within the proximal femur during gait and falls: implications for osteoporotic fracture.
Osteoporos Int
. July 1995;5(3):252-261.
1973
Pugh JW, Rose RM, Radin EL. A structural model for the mechanical behavior of trabecular bone.
J Biomech
. 1973;6(6):657-670.
1977
Carter DR, Hayes WC. The compressive behavior of bone as a two-phase porous structure.
J Bone Joint Surg
. 1977;59A(7):954-962.
1970
Galante J, Rostoker W, Ray RD. Physical properties of trabecular bone.
Calcif Tiss Res
. 1970;5(1):236-246.
1983
Martens M, Van Audekercke R, Delport P, De Meester P, Mulier JC. The mechanical characteristics of cancellous bone at the upper femoral region.
J Biomech
. 1983;16(12):971-983.
1976
Burstein AH, Reilly DT, Martens M. Aging of bone tissue: mechanical properties.
J Bone Joint Surg
. 1976;58A(1):82-86.
1970
Singh M, Nagrath AR, Maini PS. Changes in trabecular pattern of the upper end of the femur as an index of osteoporosis.
J Bone Joint Surg
. April 1970;52A(3):457-467.
1980
Brown TD, Ferguson AB Jr. Mechanical property distributions in the cancellous bone of the human proximal femur.
Acta Orthop Scand
. 1980;51(1):429-437.
1977
Bonfield W, Grynpas MD. Anisotropy of the Young's modulus of bone.
Nature
. December 1, 1977;270:453-454.
1970
McElhaney JH, Fogle JL, Melvin JW, Haynes RR, Roberts VL, Alem NM. Mechanical properties of cranial bone.
J Biomech
. 1970;3(5):495-511.
1988
Rice JC, Cowin SC, Bowman JA. On the dependence of the elasticity and strength of cancellous bone on apparent density.
J Biomech
. 1988;21(2):155-168.
1976
Lindahl O. Mechanical properties of dried defatted spongy bone.
Acta Orthop Scand
. 1976;47(1):11-19.
1970
Currey JD. The mechanical properties of bone.
Clin Orthop Relat Res
. November–December 1970;73:210-231.
Cited By (3)
Year
Entry
2019
Wood Z, Lynn L, Nguyen JT, Black MA, Patel M, Barak MM. Are we crying wolff? 3D printed replicas of trabecular bone structure demonstrate higher stiffness and strength during off-axis loading.
Bone
. October 2019;127:635-645.
2018
Zhao S, Arnold M, Ma S, Abel RL, Cobb JP, Hansen U, Boughton O. Standardizing compression testing for measuring the stiffness of human bone.
Bone Joint Res
. August 2018;7(8):524-538.
2007
Öhman C, Baleani M, Perilli E, Dall’Ara E, Tassani S, Baruffaldi F, Viceconti M. Mechanical testing of cancellous bone from the femoral head: experimental errors due to off-axis measurements.
J Biomech
. 2007;40(11):2426-2433.