Purpose: Accurate quantification of bone microstructure plays a significant role in understanding bone mechanics and response to disease or treatment. High-resolution peripheral quantitative computed tomography (HR-pQCT) allows for the quantification of trabecular and cortical structurein vivo, with the capability of generating images at multiple voxel sizes (41, 82, and 123 μm). The aim of this study was to characterize the effect of voxel size on structural measures of trabecular and cortical bone and to determine accuracy in reference to micro-CT (µCT), the gold standard for bone microstructure quantification.
Methods: Seventeen radii from human cadaver specimens were imaged at each HR-pQCT voxel size and subsequently imaged using µCT. Bone density and microstructural assessment was performed in both the trabecular and cortical compartments, including cortical porosity quantification. Two distinct analysis techniques were applied to the 41 μm HR-pQCT data: the standard clinical indirect analysis and a direct analysis requiring no density or structural model assumptions. Analysis parameters were adjusted to enable segmentation and structure extraction at each voxel size.
Results: For trabecular microstructural measures, the 41 μm HR-pQCT data displayed the strongest correlations and smallest errors compared to µCT data. The direct analysis technique applied to the 41 μm data yielded an additional improvement in accuracy, especially for measures of trabecular thickness. The 123 μm data performed poorly, with all microstructural measures either having moderate or nonsignificant correlations with µCT data. Trabecular densitometric measures showed strong correlations to µCT data across all voxel sizes. Cortical thickness was strongly correlated with µCT values across all HR-pQCT voxel sizes. The accuracy of cortical porosity parameters was highly dependent on voxel size; again, the 41 μm data was most strongly correlated. Measures of cortical density and pore diameter at all HR-pQCT voxel sizes had either weak or nonsignificant correlations.
Conclusions: This study demonstrates the effect of voxel size on the accuracy of HR-pQCT measurements of trabecular and cortical microstructure and presents parameters for HR-pQCT analysis at nonstandard resolutions. For all parameters measured, correlations were strongest at 41 μm. Weak correlations for porosity measures indicate that a better understanding of pore structure and resolution dependence is needed.