1Orthopaedic Biomechanics Laboratory, VA Medical Center, Nashville, Tennessee, U.S.A.
2Department of Orthopaeaic Surgery, Sahlgren Hospital, Goteborg, Sweden
Abstract and keywords
The in vitro viscoelastic “creep” behavior was examined in 18 cadaveric human lumbar motion segments subjected to static axial compressive loads. Axial deformation was followed for 30 min under constant applied load. Compressive material constants (moduli and viscosity coefficients) were then determined for each intervertebral disc using a linerization method based on a Taylor series expansion of experimental data for the “three parameter” viscoelastic creep model. The degree of disc degeneration and bone mineral content (BMC) were also assessed. Good correlation between the experimentally determined and model predicted strain values were found, with the average error