Three prototype anthropomorphic test devices (ATD) were fabricated in order to evaluate the biofidelity of a newly design THOR 5th percentile female ATD [1]. This paper focuses on the biofidelity responses derived from testing one of these ATDs. There were a total of twenty‐three biofidelity test conditions that included the head, neck, shoulder, thorax, abdomen, knee‐thigh‐hip complex, and lower extremity [2]. Three repeated tests were conducted on a single ATD for each test condition. The biofidelity was objectively scored in accordance with NHTSA’s Biofidelity Ranking System (BioRank) [3]. The BioRank score of each body region was less than 2.0, corresponding to “good” biofidelity and a few less than 1.0, corresponding to “excellent” biofidelity. The overall BioRank score of the dummy was 1.28, which corresponds to “good” biofidelity.
Keywords:
Anthropomorphic test device, biofidelity, BioRank, THOR 5th percentile female, anthropometry