wbldb
home
|
authors
|
theses
Rhule, Heather
1
;
Stricklin, Jim
2
;
Moorhouse, Kevin
1
;
Donnelly, Bruce
3
Improvements to NHTSA’s biofidelity ranking system and application to the evaluation of the THOR 5th female dummy
Proceedings of the 2018 International IRCOBI Conference on the Biomechanics of Injury
Affiliations
1
NHTSA Vehicle Research and Test Center
in East Liberty, Ohio, USA
2
Transportation Research Center Inc.
, Ohio, USA
3
Biomechanics Research Associates, Ohio, USA
Links
URL:
http://www.ircobi.org/wordpress/downloads/irc18/pdf-files/12.pdf
Cited Works (3)
Year
Entry
2009
Rhule H, Moorhouse K, Donnelly B, Stricklin J. Comparison of WorldSID and ES-2re biofidelity using an updated biofidelity ranking system. In:
Proceedings of the 21st International Technical Conference on the Enhanced Safety of Vehicles (ESV)
. June 15-18, 2009; Stuttgart, Germany.
2013
Rhule H, Donnelly B, Moorhouse K, Kang YS. A methodology for generating objective targets for quantitatively assessing the biofidelity of crash test dummies. In:
Proceedings of the 23rd International Technical Conference on the Enhanced Safety of Vehicles (ESV)
. May 27-30, 2013; Seoul, South Korea.
2002
Rhule HH, Maltese MR, Donnelly BR, Eppinger RH, Brunner JK, Bolte JH IV. Development of a new biofidelity ranking system for anthropomorphic test devices.
Stapp Car Crash J
. 2002;46:477-512. SAE 2002-22-0024.
Cited By (6)
Year
Entry
2018
Wang ZJ, Lee E, Bolte J IV, Below J, Loeber B, Ramachandra R, Greenlees B, Guck D. Biofidelity evaluation of THOR 5th percentile female ATD. In:
Proceedings of the 2018 International IRCOBI Conference on the Biomechanics of Injury
. September 12-14, 2018; Athens, Greece.567-592.
2020
Albert DL. A comparison of two versions of the biofidelity ranking system (BioRank): implications on THOR-50M and THOR-05F biofidelity evaluations. In:
Proceedings of the 2020 International IRCOBI Conference on the Biomechanics of Injury
. 2020; Munich, Germany.659-678.
2021
Kang Y-S, Agnew AM. Biomechanical response corridors of 50th percentile female human ribs in anterior-posterior loading. In:
Proceedings of the 2021 International IRCOBI Conference on the Biomechanics of Injury
. September 8-10, 2021; Online.794-796.
2022
Wang ZJ, Zaseck LW, Reed MP. THOR-AV 50th percentile male biofidelity evaluation in 25° and 45° seatback angle test conditions with a semi-rigid seat. In:
Proceedings of the 2022 International IRCOBI Conference on the Biomechanics of Injury
. September 14-16, 2022; Porto, Portugal.288-308.
2022
Wang ZJ, Richard O, Lebarbé M, Uriot J, Kabadayi E, Kleessen C. Biomechanical responses of THOR-AV in a semi-rigid seat that mimics the front and rear seat of a midsize car. In:
Proceedings of the 2022 International IRCOBI Conference on the Biomechanics of Injury
. September 14-16, 2022; Porto, Portugal.401-417.
2020
Albert DL. Variations in user implementation of the CORA rating metric.
Stapp Car Crash J
. November 2020;64:1-30.