2007 |
Perilli E, Baleani M, Öhman C, Baruffaldi F, Viceconti M. Structural parameters and mechanical strength of cancellous bone in the femoral head in osteoarthritis do not depend on age. Bone. November 2007;41(5):760-768. |
20 |
14 |
2011 |
Öhman C, Baleani M, Pani C, Taddei F, Alberghini M, Viceconti M, Manfrini M. Compressive behaviour of child and adult cortical bone. Bone. October 2011;49(4):769-776. |
16 |
15 |
2021 |
Winsor C, Li X, Qasim M, Henak CR, Pickhardt PJ, Ploeg H, Viceconti M. Evaluation of patient tissue selection methods for deriving equivalent density calibration for femoral bone quantitative CT analyses. Bone. February 2021;143:115759. |
4 |
3 |
2005 |
Viceconti M, Olsen S, Nolte L-P, Burton K. Extracting clinically relevant data from finite element simulations. Clin Biomech (Bristol, Avon). June 2005;20(5):451-454. |
40 |
33 |
2008 |
Helgason B, Perilli E, Schileo E, Taddei F, Brynjólfsson S, Viceconti M. Mathematical relationships between bone density and mechanical properties: a literature review. Clin Biomech (Bristol, Avon). 2008;23(2):135-146. |
111 |
95 |
2011 |
Tassani S, Particelli F, Perilli E, Traina F, Baruffaldi F, Viceconti M. Dependence of trabecular structure on bone quantity: a comparison between osteoarthritic and non-pathological bone. Clin Biomech (Bristol, Avon). July 2011;26:632-639. |
3 |
3 |
1996 |
Cristofolini L, Viceconti M, Cappello A, Toni A. Mechanical validation of whole bone composite femur models. J Biomech. April 1996;29(4):525-535. |
33 |
28 |
2004 |
Viceconti M, Davinelli M, Taddei F, Cappello A. Automatic generation of accurate subject-specific bone finite element models to be used in clinical studies. J Biomech. 2004;37(10):1597-1605. |
30 |
25 |
2006 |
Taddei F, Cristofolini L, Martelli S, Gill HS, Viceconti M. Subject-specific finite element models of long bones: an in vitro evaluation of the overall accuracy. J Biomech. 2006;39(13):2457-2467. |
57 |
43 |
2007 |
Öhman C, Baleani M, Perilli E, Dall’Ara E, Tassani S, Baruffaldi F, Viceconti M. Mechanical testing of cancellous bone from the femoral head: experimental errors due to off-axis measurements. J Biomech. 2007;40(11):2426-2433. |
40 |
26 |
2007 |
Cristofolini L, Juszczyk M, Martelli S, Taddei F, Viceconti M. In vitro replication of spontaneous fractures of the proximal human femur. J Biomech. 2007;40(13):2837-2845. |
32 |
22 |
2007 |
Schileo E, Taddei F, Malandrino A, Cristofolini L, Viceconti M. Subject-specific finite element models can accurately predict strain levels in long bones. J Biomech. 2007;40(13):2982-2989. |
68 |
58 |
2008 |
Schileo E, Taddei F, Cristofolini L, Viceconti M. Subject-specific finite element models implementing a maximum principal strain criterion are able to estimate failure risk and fracture location on human femurs tested in vitro. J Biomech. 2008;41(2):356-367. |
61 |
50 |
2008 |
Perilli E, Baleani M, Öhman C, Fognani R, Baruffaldi F, Viceconti M. Dependence of mechanical compressive strength on local variations in microarchitecture in cancellous bone of proximal human femur. J Biomech. 2008;41(2):438-446. |
39 |
34 |
2008 |
Schileo E, Dall’Ara E, Taddei F, Malandrino A, Schotkamp T, Baleani M, Viceconti M. An accurate estimation of bone density improves the accuracy of subject-specific finite element models. J Biomech. August 7, 2008;41(11):2483-2491. |
76 |
59 |
2010 |
Cristofolini L, Conti G, Juszczyk M, Cremonini S, Sint Jan SV, Viceconti M. Structural behaviour and strain distribution of the long bones of the human lower limbs. J Biomech. March 22, 2010;43(5):826-835. |
12 |
8 |
2010 |
Tassani S, Öhman C, Baleani M, Baruffaldi F, Viceconti M. Anisotropy and inhomogeneity of the trabecular structure can describe the mechanical strength of osteoarthritic cancellous bone. J Biomech. April 19, 2010;43(6):1160-1166. |
9 |
7 |
2011 |
Tassani S, Öhman C, Baruffaldi F, Baleani M, Viceconti M. Volume to density relation in adult human bone tissue. J Biomech. 2011;44(1):103-108. |
11 |
8 |
2011 |
Dall'Ara E, Öhman C, Baleani M, Viceconti M. Reduced tissue hardness of trabecular bone is associated with severe osteoarthritis. J Biomech. May 17, 2011;44(8):1593-1598. |
3 |
3 |
2011 |
Juszczyk MM, Cristofolini L, Viceconti M. The human proximal femur behaves linearly elastic up to failure under physiological loading conditions. J Biomech. August 11, 2011;44(12):2259-2266. |
13 |
7 |
2012 |
Grassi L, Schileo E, Taddei F, Zani L, Juszczyk M, Cristofolini L, Viceconti M. Accuracy of finite element predictions in sideways load configurations for the proximal human femur. J Biomech. January 10, 2012;45(2):394-399. |
28 |
22 |
2014 |
Dall’Ara E, Barber D, Viceconti M. About the inevitable compromise between spatial resolution and accuracy of strain measurement for bone tissue: a 3D zero-strain study. J Biomech. September 22, 2014;47(12):2956-2963. |
38 |
20 |
2017 |
Palanca M, Bodey AJ, Giorgi M, Viceconti M, Lacroix D, Cristofolini L, Dall'Ara E. Local displacement and strain uncertainties in different bone types by digital volume correlation of synchrotron microtomograms. J Biomech. June 14, 2017;58:27-36. |
20 |
11 |
2018 |
Modenese L, Montefiori E, Wang A, Wesarg S, Viceconti M, Mazzà C. Investigation of the dependence of joint contact forces on musculotendon parameters using a codified workflow for image-based modelling. J Biomech. May 17, 2018;73:108-118. |
9 |
7 |
2023 |
Slowik JS, Davico G, Viceconti M. Comparison of a single-view image-based system to a multi-camera marker-based system for human static pose estimation. J Biomech. October 2023;159:111746. |
0 |
0 |
2023 |
Princelle D, Davico G, Viceconti M. Comparative validation of two patient-specific modelling pipelines for predicting knee joint forces during level walking. J Biomech. October 2023;159:111758. |
0 |
0 |
2014 |
Chen Y, Pani M, Taddei F, Mazzà C, Li X, Viceconti M. Large-scale finite element analysis of human cancellous bone tissue micro computer tomography data: a convergence study. J Biomech Eng. October 2014;136(10):101013. |
10 |
6 |
2015 |
Palanca M, Tozzi G, Cristofolini L, Viceconti M, Dall'Ara E. Three-dimensional local measurements of bone strain and displacement: comparison of three digital volume correlation approaches. J Biomech Eng. July 2015;137(7):071006. |
29 |
13 |
2017 |
Chen Y, Dall’Ara E, Sales E, Manda K, Wallace R, Pankaj P, Viceconti M. Micro-CT based finite element models of cancellous bone predict accurately displacement once the boundary condition is well replicated: a validation study. J Mech Behav Biomed Mater. January 2017;65:644-651. |
31 |
18 |
2007 |
Perilli E, Baruffaldi F, Visentin M, Bordini B, Traina F, Cappello A, Viceconti M. MicroCT examination of human bone specimens: effects of polymethylmethacrylate embedding on structural parameters. J Microsc (Oxford). 2007;225(pt 2):192-200. |
18 |
10 |
1998 |
Viceconti M, Bellingeri L, Cristofolini L, Toni A. A comparative study on different methods of automatic mesh generation of human femurs. Med Eng Phys. January 1998;20(1):1-10. |
42 |
37 |
1998 |
Zannoni C, Mantovani R, Viceconti M. Material properties assignment to finite element models of bone structures: a new method. Med Eng Phys. December 1998;20(10):735-740. |
30 |
24 |
2004 |
Taddei F, Pancanti A, Viceconti M. An improved method for the automatic mapping of computed tomography numbers onto finite element models. Med Eng Phys. 2004;26(1):61-69. |
51 |
42 |
2007 |
Taddei F, Schileo E, Helgason B, Cristofolini L, Viceconti M. The material mapping strategy influences the accuracy of ct-based finite element models of bones: an evaluation against experimental measurements. Med Eng Phys. 2007;29(9):973-979. |
57 |
45 |
2008 |
Helgason B, Taddei F, Pálsson H, Schileo E, Cristofolini L, Viceconti M, Brynjolfsson S. A modified method for assigning material properties to FE models of bones. Med Eng Phys. May 2008;30(4):444-453. |
33 |
26 |
2011 |
Grassi L, Hraiech N, Schileo E, Ansaloni M, Rochette M, Viceconti M. Evaluation of the generality and accuracy of a new mesh morphing procedure for the human femur. Med Eng Phys. 2011;33(1):112-120. |
5 |
5 |
2010 |
Cristofolini L, Schileo E, Juszczyk M, Taddei F, Martelli S, Viceconti M. Mechanical testing of bones: the positive synergy of finite–element models and in vitro experiments. Philos Trans R Soc A-Math Phys Eng Sci. June 13, 2010;368(1920):2725-2763. |
24 |
17 |
2017 |
Costa MC, Tozzi G, Cristofolini L, Danesi V, Viceconti M, Dall’Ara E. Micro finite element models of the vertebral body: validation of local displacement predictions. PLoS One. July 11, 2017;12(7):e0180151. |
25 |
15 |
2009 |
Cristofolini L, Juszczyk M, Taddei F, Viceconti M. Strain distribution in the proximal human femoral metaphysis. Proc Inst Mech Eng Part H-J Eng Med. April 2009;2223(3):273-288. |
17 |
9 |