The results of the development of a four-degree-of-freedom, lumped parameter model of the vibration response characteristics of the human hand are presented. For this study dynamic compliance measurements were made on 75 foundry workers. Curve fitting techniques were then employed to identify the values of the model parameters that yielded empirically generated dynamic compliance curves that correlated well with the measured dynamic compliance values. The agreement was good between 20 Hz and 1000 Hz in the X- and Y-directions. The agreement was good between 20 Hz and 1000 Hz in the Z-direction.