1994 |
Linde F. Elastic and viscoelastic properties of trabecular bone by a compression testing approach. Dan Med Bull. April 1994;41(2):119-138. |
27 |
26 |
1985 |
Linde F, Hvid I, Jensen NC. Material properties of cancellous bone in repetitive axial loading. Eng Med. October 1985;14(4):173-177. |
22 |
11 |
1988 |
Linde F, Gøthgen CB, Hvid I, Pongsoipetch B, Bentzen S. Mechanical properties of trabecular bone by a non‐destructive compression testing approach. Eng Med. 1988;17(1):23-29. |
38 |
27 |
1987 |
Linde F, Hvid I. Stiffness behaviour of trabecular bone specimens. J Biomech. 1987;20(1):83-89. |
59 |
52 |
1989 |
Linde F, Hvid I. The effect of constraint on the mechanical behaviour of trabecular bone specimens. J Biomech. 1989;22(5):485-490. |
102 |
91 |
1989 |
Odgaard A, Hvid I, Linde F. Compressive axial strain distributions in cancellous bone specimens. J Biomech. 1989;22(8-9):829-835. |
59 |
54 |
1989 |
Hvid I, Bentzen SM, Linde F, Mosekilde L, Pongsoipetch B. X-ray quantitative computed tomography: the relations to physical properties of proximal tibial trabecular bone specimens. J Biomech. 1989;22(8-9):837-844. |
66 |
60 |
1990 |
Linde F, Pongsoipetch B, Frich LH, Hvid I. Three-axial strain controlled testing applied to bone specimens from the proximal tibial epiphysis. J Biomech. 1990;23(11):1167-1172. |
23 |
20 |
1991 |
Odgaard A, Linde F. The underestimation of Young's modulus in compressive testing of cancellous bone specimens. J Biomech. 1991;24(8):691-698. |
120 |
109 |
1991 |
Linde F, Nørgaard P, Hvid I, Odgaard A, Søballe K. Mechanical properties of trabecular bone: dependency on strain rate. J Biomech. 1991;24(9):803-809. |
82 |
79 |
1991 |
Røhl L, Larsen E, Linde F, Odgaard A, Jørgensen J. Tensile and compressive properties of cancellous bone. J Biomech. 1991;24(12):1143-1149. |
74 |
72 |
1992 |
Linde F, Hvid I, Madsen F. The effect of specimen geometry on the mechanical behaviour of trabecular bone specimens. J Biomech. 1992;25(4):359-368. |
124 |
122 |
1993 |
Linde F, Sørensen HCF. The effect of different storage methods on the mechanical properties of trabecular bone. J Biomech. 1993;26(10):1249-1252. |
110 |
108 |
1997 |
Ding M, Dalstra M, Danielsen CC, Kabel J, Hvid I, Linde F. Age variations in the properties of human tibial trabecular bone. J Bone Joint Surg. November 1997;79B(6):995-1002. |
52 |
42 |
2000 |
Nafei A, Danielsen CC, Linde F, Hvid I. Properties of growing trabecular ovine bone, I: mechanical and physical properties. J Bone Joint Surg. August 2000;82B(6):910-920. |
20 |
19 |
2000 |
Nafei A, Kabel J, Odgaard A, Linde F, Hvid I. Properties of growing trabecular ovine bone, II: architectural and mechanical properties. J Bone Joint Surg. August 2000;82B(6):921-927. |
10 |
10 |
1989 |
Linde F, Hvid I, Pongsoipetch B. Energy absorptive properties of human trabecular bone specimens during axial compression. J Orthop Res. May 1989;7(3):432-439. |
47 |
39 |
2002 |
Ding M, Odgaard A, Linde F, Hvid I. Age-related variations in the microstructure of human tibial cancellous bone. J Orthop Res. May 2002;20(3):615-621. |
48 |
45 |